WEBVTT

1
00:00:00.011 --> 00:00:02.064
Hello everyone.

2
00:00:02.297 --> 00:00:04.569
Welcome to Cimbra. I'm Sandy Curth,

3
00:00:05.272 --> 00:00:07.597
one of the co-founders of Forma Systems,

4
00:00:07.598 --> 00:00:11.819
the company that has developed the Cimbra Structural Optimization Tool.

5
00:00:12.490 --> 00:00:15.774
This will just be a brief walkthrough of its functionality and how to get

6
00:00:15.775 --> 00:00:18.771
started. So, when you log in,

7
00:00:18.802 --> 00:00:21.185
you'll see this page, ah,

8
00:00:21.186 --> 00:00:24.192
where you can set up a new project, and you can access it as

9
00:00:24.193 --> 00:00:26.298
your Material and Mold Library.

10
00:00:26.948 --> 00:00:30.280
So, if you're new to the tool, and you want to get set up

11
00:00:30.281 --> 00:00:34.811
with the specifications that make the most sense for your precast plant and

12
00:00:34.812 --> 00:00:39.327
your manufacturers, then start by heading over to the Mold and Material Library.

13
00:00:41.299 --> 00:00:45.852
So, in here, you can see that there's a variety of inputs to

14
00:00:45.853 --> 00:00:50.816
configure the Mold Genie geometry that you have available for a given project.

15
00:00:52.530 --> 00:00:55.824
So, you can adjust things like the stem width,

16
00:00:55.825 --> 00:01:00.841
the number of stems, you know, maybe you're just doing

17
00:01:00.842 --> 00:01:02.998
a single T,

18
00:01:02.999 --> 00:01:05.900
or maybe your focus is more on the double T.

19
00:01:07.208 --> 00:01:12.301
You can adjust the depth, Peace. And

20
00:01:12.302 --> 00:01:14.966
all of this can be done in Metric or Imperial, so depending on where

21
00:01:14.967 --> 00:01:17.341
you're working, maybe this will make a little more sense.

22
00:01:20.087 --> 00:01:24.653
You know, you can adjust the different standard ratios for

23
00:01:24.654 --> 00:01:29.506
your design. And so once you've configured a mold,

24
00:01:29.842 --> 00:01:33.454
then you can save that mold to your library.

25
00:01:33.455 --> 00:01:35.629
First, you have to give it a name, so we'll call this,

26
00:01:35.630 --> 00:01:38.222
CustomMold1.

27
00:01:38.223 --> 00:01:41.125
We'll save it to our library, and then you can see here we have

28
00:01:41.126 --> 00:01:43.759
this library of molds, so some of these are,

29
00:01:43.770 --> 00:01:47.885
standard designs you might find in the PCI Precast Handbook,

30
00:01:47.896 --> 00:01:51.833
or other designs that we've just come up with as we're experimenting.

31
00:01:51.834 --> 00:01:53.842
So,

32
00:01:53.843 --> 00:01:56.183
that's basically the mold library.

33
00:01:56.519 --> 00:01:59.258
Then you're going to want to go to the material library,

34
00:01:59.681 --> 00:02:04.225
where you'll see we already have pre-populated a relatively wide variety

35
00:02:04.226 --> 00:02:07.397
of concrete mixes, and, rebar as well as,

36
00:02:07.407 --> 00:02:09.636
strand type. So,

37
00:02:09.637 --> 00:02:11.960
again, here, if you would like, you can,

38
00:02:11.971 --> 00:02:14.441
you can configure and add your own materials. So,

39
00:02:14.747 --> 00:02:17.184
once you have some molds and materials, then it makes sense for you,

40
00:02:17.963 --> 00:02:20.137
you can begin a new project.

41
00:02:20.426 --> 00:02:23.123
And just to save us a little time, I'll just open an existing one.

42
00:02:24.489 --> 00:02:28.966
So, here, you can see a project where I have a couple different,

43
00:02:28.977 --> 00:02:33.583
span and load conditions. And I've started by setting

44
00:02:34.213 --> 00:02:36.403
my first objective as carbon.

45
00:02:36.404 --> 00:02:39.213
So, the goal with this particular optimization will be to find the,

46
00:02:39.224 --> 00:02:42.103
the system or the,

47
00:02:42.104 --> 00:02:45.227
the set of systems that make the most sense for this project in terms

48
00:02:45.228 --> 00:02:49.557
of minimizing the amount of carbon that's going into the products produced.

49
00:02:51.004 --> 00:02:54.106
You can see the governing code is ACI 318.

50
00:02:54.107 --> 00:02:56.187
As Simberg grows, we'll support more codes.

51
00:02:56.197 --> 00:03:00.142
there's a clear cover requirement here that you can add in your deflection limit.

52
00:03:00.153 --> 00:03:02.903
if you'd like to see it, if it's possible to make the design without

53
00:03:02.904 --> 00:03:05.878
needing any passive rebar, you can toggle that here as well.

54
00:03:05.889 --> 00:03:09.557
so you can see that I've selected a little variety of molds.

55
00:03:09.568 --> 00:03:11.572
you know, some, some standard,

56
00:03:11.583 --> 00:03:14.115
options like a DT24, DT26.

57
00:03:14.238 --> 00:03:17.298
and then what we've done here is once you've configured the all of your

58
00:03:17.299 --> 00:03:19.485
selections, you can push generate designs.

59
00:03:20.516 --> 00:03:23.412
And what that'll do is it'll produce a design matrix.

60
00:03:23.413 --> 00:03:25.806
So here, when we ran this optimization,

61
00:03:25.817 --> 00:03:28.824
we evaluated a little bit over 400,000 designs,

62
00:03:28.834 --> 00:03:33.398
found 12 that were feasible and well within the parameters of manufacturability

63
00:03:33.399 --> 00:03:38.100
as defined by your mold geometry. And what you can do here now is

64
00:03:38.101 --> 00:03:42.844
you can across the different mold options and different design options and

65
00:03:42.845 --> 00:03:45.270
see what offers the greatest advantage.

66
00:03:45.271 --> 00:03:48.405
So, if we select one of these designs,

67
00:03:49.535 --> 00:03:54.119
and then scroll down, you can see all of your typical structural validation

68
00:03:54.120 --> 00:03:58.677
information, and you can also run back the optimization itself,

69
00:03:58.678 --> 00:04:03.576
which can be kind of interesting. So you can see Thank this comparison

70
00:04:03.577 --> 00:04:07.043
across the different free variables, so the number of strands,

71
00:04:07.285 --> 00:04:09.432
their position, that type of thing.

72
00:04:12.552 --> 00:04:16.899
And then you'll see the, the finalized design for that,

73
00:04:16.910 --> 00:04:21.597
particular option that you selected, as well as a collection of the

74
00:04:21.598 --> 00:04:24.129
typical structural checks you'd expect,

75
00:04:24.140 --> 00:04:29.354
you know, bending moment, you

76
00:04:29.355 --> 00:04:31.374
can look at the the,

77
00:04:31.375 --> 00:04:34.146
typical checks you would find in, you know,

78
00:04:34.147 --> 00:04:37.510
a standard structural validation software for precast design.

79
00:04:38.310 --> 00:04:41.892
You can also download a report or download a spreadsheet,

80
00:04:41.893 --> 00:04:44.845
an Excel sheet. That has all of this data in it so you can

81
00:04:44.846 --> 00:04:48.256
quickly compare, or pass along the data to someone else on your team for

82
00:04:48.257 --> 00:04:50.627
bidding, that sort of thing. So,

83
00:04:50.800 --> 00:04:53.170
that's the general overview of the tool,

84
00:04:53.181 --> 00:04:56.203
please give it a try, let us know what you think, and thank you

85
00:04:56.204 --> 00:04:56.560
so much.